北京大学城洗浴中心-北京大学城洗浴中心

德阳附近有没有服务

 
Home page Company profile news information Product display Technology Center Qualification certificate Sales network Project performance contact us
 please wait a moment...
Project list
       Anti corrosion water tank
       Anti corrosion of sewage tank
       Anti corrosion of cement tank
       San Bu Wu you
       Three oil two cloth
       Three cloth four oil
       Three cloth and four coating
       FRP anticorrosion
       Two cloths and three oils
       FRP anticorrosion of water tank
       Anticorrosion of FRP chimney
       Anti corrosion of epoxy FRP
       FRP lining
       Anticorrosion of FRP pool wall
 
contact us

Name: Jiangsu Xinda high altitude Engineering Co., Ltd
East side of Yancheng Road, Jiangsu Province
Contact person: Wang Weiyin (General Manager)
Mobile phone: 19962399555
    19962377555
Tel: 0515-88725999
Website address: ginajacobi.com

 
Anti corrosion water tank
 

Anti corrosion water tank

product details

Construction of resin glass fiber reinforced plastic
The construction of resin glass fiber reinforced plastic should adopt hand paste method. Hand paste method is divided into batch method and continuous method. Phenolic FRP should be constructed by intermittent method.
The construction before the laying of resin glass fiber reinforced plastic should meet the following requirements:
1 sealing bottom layer: on the surface of the treated base course, the sealing material shall be evenly applied, and there shall be no defects such as missing coating and sagging, and the natural curing time shall not be less than 24h.
2 repair layer: at the concave and uneven part of the base course, the resin mortar should be used to repair and fill, and the natural curing should not be less than 24h. Phenolic glass fiber reinforced plastics or furan glass fiber reinforced plastics can be epoxy resin or vinyl ester resin, unsaturated polyester resin mortar
Repair and scrape the base course.  
The construction of intermittent resin glass fiber reinforced plastic lining layer shall meet the following requirements:
1 glass fiber cloth should be cut. Polyester fabric should be pre treated with anti shrinkage.
2. First, brush a layer of bedding rubber evenly, and then apply a layer of fiber reinforced material, which must be close and clear of bubbles, and then apply a layer of rubber on it. The rubber should be full.
After the surface is trimmed, the following layers shall be paved according to the above procedures until the number or thickness of the layers meets the design requirements.
4. For each layer of lining, the quality of the previous layer shall be checked. In case of defects such as burr, delamination and bubbles, repair shall be carried out.
5. During lining, the lap width of the same layer of fiber reinforced materials shall not be less than 50 mm; the joints of the upper and lower layers of fiber reinforced materials shall be staggered, and the staggered distance shall not be less than 50 mm; 1-2 layers of fiber reinforced materials shall be added at the internal and external corners.
The construction of continuous resin glass fiber reinforced plastic lining layer shall meet the following requirements:
1. The number or thickness of one-time continuous lining on the plane should not produce slippage, and shell or delamination should not occur after curing.
2. The number of layers or thickness of one-time continuous lining of facade shall not produce slippage, and shell or delamination shall not occur after curing.
3. During lining, the joints of upper and lower layers of fiber reinforced materials shall be staggered, and the staggered distance shall not be less than 50 mm; 1-2 layers of fiber reinforced materials shall be added at the internal and external corners.
4. The construction of the next continuous paving layer shall be carried out after the curing of the previous continuous lining layer.
5. After continuous paving to the number of layers or thickness required by the design, it should be naturally solidified for 24h before the cover layer construction can be carried out.  
The construction of resin glass fiber reinforced plastic cover layer should be evenly coated with surface rubber. When painting for more than two times, after the first curing, brush the next one.
When the resin glass reinforced plastic is used as the isolation layer of the whole surface layer or block surface layer of resin mortar, resin mortar and water glass concrete, after the last layer of cloth is paved, a layer of rubber material shall be applied, and a layer of fine aggregate with particle size of 0.7-1.2mm shall be evenly scattered.  


enclosure

Hits: 320 entry time: October 09, 2019 15:42:08【 Print this page 】【 return

Copyright: Jiangsu Xinda high altitude Engineering Co., Ltd. copyright notice address: south side of Dongjin Middle Road, Yancheng City, Jiangsu Province
Contact: Wang Weiyin (General Manager) Tel: 0515-88725999 Mobile: (0) 19962399555 19962377555 website optimization QQ: 97595105
Key words of the website: [anti-corrosion of water pool] [anti-corrosion of sewage pool] [anticorrosion of cement pool] [FRP anticorrosion of pool] [three cloth and five oil] [three oil and two cloth] [anticorrosion of FRP chimney]